Single & Two-Storey Rear Residential Extension — Illustrative NRM2 Takeoff
Demonstrates how domestic refurbishment and extension packs separate enabling demolition/propping, trench-fill substructures, structural box-frame steels, cavity masonry, warm-roof carpentry, and Part L/F internal finishes.
| Ref / NRM2 | Description | Qty | Unit | Notes |
|---|---|---|---|---|
| RE-01 · 04 Alterations | Break out existing rear cavity loadbearing wall (2400mm opening); temporary Acrow/Strongboy needling & cart-away skips | 1.00 | item | Separated from new-build brickwork |
| RE-02 · 05 Excavation | Trench excavation for 600mm wide strip footings to 1.25m depth; includes 50mm compressible clay-heave board against existing drains | 16.50 | m3 | Clay soil bulking factor noted |
| RE-03 · 14 Masonry | Facing brickwork outer leaf (F2 durability, stretcher bond) + 100mm PIR full-fill insulation + 100mm dense block inner leaf | 54.20 | m2 | Net of window & bifold openings |
| RE-04 · 15 Steelwork | Fabricated S355 steel goal-post box frame (203x203x46 UC columns + 254x146x37 UB lintel beams) with bolted splice plates & primer | 1.42 | t | Matched to structural engineer GA |
| RE-05 · 17 Roofing | Warm flat roof assembly: C24 joists @ 400mm cts, 18mm OSB3 deck, VCL, 150mm PIR insulation & 1.5mm EPDM single-ply membrane | 36.80 | m2 | Excludes rooflight opening |